Abstract:
The Vann De Gra is very famous in the electrical industry, high-voltage X-rays, nuclear
physics, and dielectric testing. It has gained its importance because of its unconventional
design and high voltage capacity with an extremely low current. However, the sensitivity
to the environment and over insulation requirements restrict its use immensely and thus
it becomes a major reason of ignorance for quite sometimes. Also, the unavailability of
an empirical model lacks its proper designing which ultimately fails to deliver e cient
performance. This problem has been analyzed sensitively and its solution has been
implemented in this research.
The designing in this research is critically analyzed and especially the problem in some
critical parts like Designing of Dome is solved by selecting the aluminum material dome
with perfect sizing by using the sphere vs charge calculation to get desired voltages. The
Te on Belt material is selected instead of rubber belt for the better performance because
Te on material is more close to "capture" electrons. The Belt is also stretched for more
charges to liberate out. But it may cause the breakage of belt, to avoid this we use soft
starting of motors using SCR Controlled voltage regulator.
While designing the generator we cannot ignore the insulation of this generator because
it possesses very high voltage with a small current that's why the insulation of internal
and external part of the generator focused on this research, some parts of the generator
must be highly insulated otherwise the charge failed to establish. The functionality of
this generator is mainly dependent on weather conditions. The electrostatic charges leak
very rapidly in moisture. The insulation is the prime factor for improvement in every
Van de Gra generator. The irregularities at the dome surface cause a leakage of charges.
So to remove this issue we polished a dome with zinc material. Further we introduce
silica gel at the outer side to remove moisture of inner region and for inside part the
generator is insulated through a vacuum pump and a bulb which generates the heat to
avoid humidity e ect.
The rate of discharge is a superior parameter of the execution of the machine than the
ideal voltage. Thus we perform two di erent tests to verify the performance of generator
one of the test is conventional voltage test using electrostatic generator and other is gap
spark tests. The results with proper testing provide a 200 kV generator with better
e ciency than the one commercially available.